If cell looks like one on right clean cell.
Hayward turbo cell cleaning instructions.
If there is no buildup it s time to re calibrate the cell.
To set turbo cell type before operation the aqua rite must be configured for the chlorinator cell that will be used.
Check salt inspect cell led s may also be on if the control is set for the wrong cell type or the cell is unplugged.
Refer to pages 19 thru 21.
Turbo cell lighting equipment pdf manual download.
Contact hayward support.
After the cell is clean go to step 1c to reset.
If there is buildup follow the procedure for cleaning the cell outlined in how to maintain and extend the life of your salt cell.
Page 12 even if a turbocell appears clean it may still equipment.
Remove the turbo cell.
Save these instructions use only hayward genuine replacement parts.
For optimum turbocell operation and life you will need to inspect your cell approximately every 3 months of operation or 500 hours and clean the cell if n.
The following guide shows how to clean a hayward aquarite turbo cell.
Get support by contacting us online.
Hayward pool products.
With daily use hard mineral deposits will build up on the electrolytic plates of the cell.
The manufacturer recommends checking the hayward aquarite turbo cell 3 4 times a year and cleaning it with a solution of water and muriatic acid to descale any deposits as required.
We are here to help with all of your hayward pool products.
How to clean your hayward salt chlorinator turbo cell.
Once removed look through the cell and inspect for scale formation light colored crusty or flaky deposits on the plates and for debris that is caught on the plates.
Smart control upgrade.
View and download hayward turbo cell configuration manual online.
Use only hayward genuine replacement parts 6.
If no deposits are visible reinstall the cell.
Turn off the power to the system and deactivate the pool pump before removing the turbo cell.
Electronic chlorinator cell test.
If cell looks like one of left go to step 1c.
Table of contents operation.
If deposits are seen use a high pressure garden hose to flush the scale off.
Clean or replace if necessary.
So the cell should produce chlorine for the first 90 minutes of 3 hours before repeating.
Inspect the turbo cell.
It is highly recommended to use a require cleaning if salt accuracy is off and or chlorine hayward cell cleaning stand as shown on the right production has diminished.
Step 1a step 1b.
Here is how to recalibrate a hayward aqua rite turbo cell in three simple steps.